power-monitor
The power-monitor
module is used to monitor the power state change. You can
only use it on the main process. You should not use this module until the ready
event of app
module gets emitted.
An example is:
var app = require('app');
app.on('ready', function() {
require('power-monitor').on('suspend', function() {
console.log('The system is going to sleep');
});
});
Event: suspend
Emitted when the system is suspending.
Event: resume
Emitted when system is resuming.
Event: on-ac
Emitted when the system changes to AC power.
Event: on-battery
Emitted when system changes to battery power.