# MessagePorts in Electron
|
|
|
|
[`MessagePort`][]s are a web feature that allow passing messages between
|
|
different contexts. It's like `window.postMessage`, but on different channels.
|
|
The goal of this document is to describe how Electron extends the Channel
|
|
Messaging model, and to give some examples of how you might use MessagePorts in
|
|
your app.
|
|
|
|
Here is a very brief example of what a MessagePort is and how it works:
|
|
|
|
```js title='renderer.js (Renderer Process)'
|
|
// MessagePorts are created in pairs. A connected pair of message ports is
|
|
// called a channel.
|
|
const channel = new MessageChannel()
|
|
|
|
// The only difference between port1 and port2 is in how you use them. Messages
|
|
// sent to port1 will be received by port2 and vice-versa.
|
|
const port1 = channel.port1
|
|
const port2 = channel.port2
|
|
|
|
// It's OK to send a message on the channel before the other end has registered
|
|
// a listener. Messages will be queued until a listener is registered.
|
|
port2.postMessage({ answer: 42 })
|
|
|
|
// Here we send the other end of the channel, port1, to the main process. It's
|
|
// also possible to send MessagePorts to other frames, or to Web Workers, etc.
|
|
ipcRenderer.postMessage('port', null, [port1])
|
|
```
|
|
|
|
```js title='main.js (Main Process)'
|
|
// In the main process, we receive the port.
|
|
ipcMain.on('port', (event) => {
|
|
// When we receive a MessagePort in the main process, it becomes a
|
|
// MessagePortMain.
|
|
const port = event.ports[0]
|
|
|
|
// MessagePortMain uses the Node.js-style events API, rather than the
|
|
// web-style events API. So .on('message', ...) instead of .onmessage = ...
|
|
port.on('message', (event) => {
|
|
// data is { answer: 42 }
|
|
const data = event.data
|
|
})
|
|
|
|
// MessagePortMain queues messages until the .start() method has been called.
|
|
port.start()
|
|
})
|
|
```
|
|
|
|
The [Channel Messaging API][] documentation is a great way to learn more about
|
|
how MessagePorts work.
|
|
|
|
## MessagePorts in the main process
|
|
|
|
In the renderer, the `MessagePort` class behaves exactly as it does on the web.
|
|
The main process is not a web page, though—it has no Blink integration—and so
|
|
it does not have the `MessagePort` or `MessageChannel` classes. In order to
|
|
handle and interact with MessagePorts in the main process, Electron adds two
|
|
new classes: [`MessagePortMain`][] and [`MessageChannelMain`][]. These behave
|
|
similarly to the analogous classes in the renderer.
|
|
|
|
`MessagePort` objects can be created in either the renderer or the main
|
|
process, and passed back and forth using the [`ipcRenderer.postMessage`][] and
|
|
[`WebContents.postMessage`][] methods. Note that the usual IPC methods like
|
|
`send` and `invoke` cannot be used to transfer `MessagePort`s, only the
|
|
`postMessage` methods can transfer `MessagePort`s.
|
|
|
|
By passing `MessagePort`s via the main process, you can connect two pages that
|
|
might not otherwise be able to communicate (e.g. due to same-origin
|
|
restrictions).
|
|
|
|
## Extension: `close` event
|
|
|
|
Electron adds one feature to `MessagePort` that isn't present on the web, in
|
|
order to make MessagePorts more useful. That is the `close` event, which is
|
|
emitted when the other end of the channel is closed. Ports can also be
|
|
implicitly closed by being garbage-collected.
|
|
|
|
In the renderer, you can listen for the `close` event either by assigning to
|
|
`port.onclose` or by calling `port.addEventListener('close', ...)`. In the main
|
|
process, you can listen for the `close` event by calling `port.on('close',
|
|
...)`.
|
|
|
|
## Example use cases
|
|
|
|
### Setting up a MessageChannel between two renderers
|
|
|
|
In this example, the main process sets up a MessageChannel, then sends each port
|
|
to a different renderer. This allows renderers to send messages to each other
|
|
without needing to use the main process as an in-between.
|
|
|
|
```js title='main.js (Main Process)'
|
|
const { BrowserWindow, app, MessageChannelMain } = require('electron')
|
|
|
|
app.whenReady().then(async () => {
|
|
// create the windows.
|
|
const mainWindow = new BrowserWindow({
|
|
show: false,
|
|
webPreferences: {
|
|
contextIsolation: false,
|
|
preload: 'preloadMain.js'
|
|
}
|
|
})
|
|
|
|
const secondaryWindow = new BrowserWindow({
|
|
show: false,
|
|
webPreferences: {
|
|
contextIsolation: false,
|
|
preload: 'preloadSecondary.js'
|
|
}
|
|
})
|
|
|
|
// set up the channel.
|
|
const { port1, port2 } = new MessageChannelMain()
|
|
|
|
// once the webContents are ready, send a port to each webContents with postMessage.
|
|
mainWindow.once('ready-to-show', () => {
|
|
mainWindow.webContents.postMessage('port', null, [port1])
|
|
})
|
|
|
|
secondaryWindow.once('ready-to-show', () => {
|
|
secondaryWindow.webContents.postMessage('port', null, [port2])
|
|
})
|
|
})
|
|
```
|
|
|
|
Then, in your preload scripts you receive the port through IPC and set up the
|
|
listeners.
|
|
|
|
```js title='preloadMain.js and preloadSecondary.js (Preload scripts)' @ts-window-type={electronMessagePort:MessagePort}
|
|
const { ipcRenderer } = require('electron')
|
|
|
|
ipcRenderer.on('port', e => {
|
|
// port received, make it globally available.
|
|
window.electronMessagePort = e.ports[0]
|
|
|
|
window.electronMessagePort.onmessage = messageEvent => {
|
|
// handle message
|
|
}
|
|
})
|
|
```
|
|
|
|
In this example messagePort is bound to the `window` object directly. It is better
|
|
to use `contextIsolation` and set up specific contextBridge calls for each of your
|
|
expected messages, but for the simplicity of this example we don't. You can find an
|
|
example of context isolation further down this page at [Communicating directly between the main process and the main world of a context-isolated page](#communicating-directly-between-the-main-process-and-the-main-world-of-a-context-isolated-page)
|
|
|
|
That means window.electronMessagePort is globally available and you can call
|
|
`postMessage` on it from anywhere in your app to send a message to the other
|
|
renderer.
|
|
|
|
```js title='renderer.js (Renderer Process)' @ts-window-type={electronMessagePort:MessagePort}
|
|
// elsewhere in your code to send a message to the other renderers message handler
|
|
window.electronMessagePort.postMessage('ping')
|
|
```
|
|
|
|
### Worker process
|
|
|
|
In this example, your app has a worker process implemented as a hidden window.
|
|
You want the app page to be able to communicate directly with the worker
|
|
process, without the performance overhead of relaying via the main process.
|
|
|
|
```js title='main.js (Main Process)'
|
|
const { BrowserWindow, app, ipcMain, MessageChannelMain } = require('electron')
|
|
|
|
app.whenReady().then(async () => {
|
|
// The worker process is a hidden BrowserWindow, so that it will have access
|
|
// to a full Blink context (including e.g. <canvas>, audio, fetch(), etc.)
|
|
const worker = new BrowserWindow({
|
|
show: false,
|
|
webPreferences: { nodeIntegration: true }
|
|
})
|
|
await worker.loadFile('worker.html')
|
|
|
|
// The main window will send work to the worker process and receive results
|
|
// over a MessagePort.
|
|
const mainWindow = new BrowserWindow({
|
|
webPreferences: { nodeIntegration: true }
|
|
})
|
|
mainWindow.loadFile('app.html')
|
|
|
|
// We can't use ipcMain.handle() here, because the reply needs to transfer a
|
|
// MessagePort.
|
|
// Listen for message sent from the top-level frame
|
|
mainWindow.webContents.mainFrame.ipc.on('request-worker-channel', (event) => {
|
|
// Create a new channel ...
|
|
const { port1, port2 } = new MessageChannelMain()
|
|
// ... send one end to the worker ...
|
|
worker.webContents.postMessage('new-client', null, [port1])
|
|
// ... and the other end to the main window.
|
|
event.senderFrame.postMessage('provide-worker-channel', null, [port2])
|
|
// Now the main window and the worker can communicate with each other
|
|
// without going through the main process!
|
|
})
|
|
})
|
|
```
|
|
|
|
```html title='worker.html'
|
|
<script>
|
|
const { ipcRenderer } = require('electron')
|
|
|
|
const doWork = (input) => {
|
|
// Something cpu-intensive.
|
|
return input * 2
|
|
}
|
|
|
|
// We might get multiple clients, for instance if there are multiple windows,
|
|
// or if the main window reloads.
|
|
ipcRenderer.on('new-client', (event) => {
|
|
const [ port ] = event.ports
|
|
port.onmessage = (event) => {
|
|
// The event data can be any serializable object (and the event could even
|
|
// carry other MessagePorts with it!)
|
|
const result = doWork(event.data)
|
|
port.postMessage(result)
|
|
}
|
|
})
|
|
</script>
|
|
```
|
|
|
|
```html title='app.html'
|
|
<script>
|
|
const { ipcRenderer } = require('electron')
|
|
|
|
// We request that the main process sends us a channel we can use to
|
|
// communicate with the worker.
|
|
ipcRenderer.send('request-worker-channel')
|
|
|
|
ipcRenderer.once('provide-worker-channel', (event) => {
|
|
// Once we receive the reply, we can take the port...
|
|
const [ port ] = event.ports
|
|
// ... register a handler to receive results ...
|
|
port.onmessage = (event) => {
|
|
console.log('received result:', event.data)
|
|
}
|
|
// ... and start sending it work!
|
|
port.postMessage(21)
|
|
})
|
|
</script>
|
|
```
|
|
|
|
### Reply streams
|
|
|
|
Electron's built-in IPC methods only support two modes: fire-and-forget
|
|
(e.g. `send`), or request-response (e.g. `invoke`). Using MessageChannels, you
|
|
can implement a "response stream", where a single request responds with a
|
|
stream of data.
|
|
|
|
```js title='renderer.js (Renderer Process)' @ts-expect-error=[18]
|
|
const makeStreamingRequest = (element, callback) => {
|
|
// MessageChannels are lightweight--it's cheap to create a new one for each
|
|
// request.
|
|
const { port1, port2 } = new MessageChannel()
|
|
|
|
// We send one end of the port to the main process ...
|
|
ipcRenderer.postMessage(
|
|
'give-me-a-stream',
|
|
{ element, count: 10 },
|
|
[port2]
|
|
)
|
|
|
|
// ... and we hang on to the other end. The main process will send messages
|
|
// to its end of the port, and close it when it's finished.
|
|
port1.onmessage = (event) => {
|
|
callback(event.data)
|
|
}
|
|
port1.onclose = () => {
|
|
console.log('stream ended')
|
|
}
|
|
}
|
|
|
|
makeStreamingRequest(42, (data) => {
|
|
console.log('got response data:', data)
|
|
})
|
|
// We will see "got response data: 42" 10 times.
|
|
```
|
|
|
|
```js title='main.js (Main Process)'
|
|
ipcMain.on('give-me-a-stream', (event, msg) => {
|
|
// The renderer has sent us a MessagePort that it wants us to send our
|
|
// response over.
|
|
const [replyPort] = event.ports
|
|
|
|
// Here we send the messages synchronously, but we could just as easily store
|
|
// the port somewhere and send messages asynchronously.
|
|
for (let i = 0; i < msg.count; i++) {
|
|
replyPort.postMessage(msg.element)
|
|
}
|
|
|
|
// We close the port when we're done to indicate to the other end that we
|
|
// won't be sending any more messages. This isn't strictly necessary--if we
|
|
// didn't explicitly close the port, it would eventually be garbage
|
|
// collected, which would also trigger the 'close' event in the renderer.
|
|
replyPort.close()
|
|
})
|
|
```
|
|
|
|
### Communicating directly between the main process and the main world of a context-isolated page
|
|
|
|
When [context isolation][] is enabled, IPC messages from the main process to
|
|
the renderer are delivered to the isolated world, rather than to the main
|
|
world. Sometimes you want to deliver messages to the main world directly,
|
|
without having to step through the isolated world.
|
|
|
|
```js title='main.js (Main Process)'
|
|
const { BrowserWindow, app, MessageChannelMain } = require('electron')
|
|
const path = require('node:path')
|
|
|
|
app.whenReady().then(async () => {
|
|
// Create a BrowserWindow with contextIsolation enabled.
|
|
const bw = new BrowserWindow({
|
|
webPreferences: {
|
|
contextIsolation: true,
|
|
preload: path.join(__dirname, 'preload.js')
|
|
}
|
|
})
|
|
bw.loadURL('index.html')
|
|
|
|
// We'll be sending one end of this channel to the main world of the
|
|
// context-isolated page.
|
|
const { port1, port2 } = new MessageChannelMain()
|
|
|
|
// It's OK to send a message on the channel before the other end has
|
|
// registered a listener. Messages will be queued until a listener is
|
|
// registered.
|
|
port2.postMessage({ test: 21 })
|
|
|
|
// We can also receive messages from the main world of the renderer.
|
|
port2.on('message', (event) => {
|
|
console.log('from renderer main world:', event.data)
|
|
})
|
|
port2.start()
|
|
|
|
// The preload script will receive this IPC message and transfer the port
|
|
// over to the main world.
|
|
bw.webContents.postMessage('main-world-port', null, [port1])
|
|
})
|
|
```
|
|
|
|
```js title='preload.js (Preload Script)'
|
|
const { ipcRenderer } = require('electron')
|
|
|
|
// We need to wait until the main world is ready to receive the message before
|
|
// sending the port. We create this promise in the preload so it's guaranteed
|
|
// to register the onload listener before the load event is fired.
|
|
const windowLoaded = new Promise(resolve => {
|
|
window.onload = resolve
|
|
})
|
|
|
|
ipcRenderer.on('main-world-port', async (event) => {
|
|
await windowLoaded
|
|
// We use regular window.postMessage to transfer the port from the isolated
|
|
// world to the main world.
|
|
window.postMessage('main-world-port', '*', event.ports)
|
|
})
|
|
```
|
|
|
|
```html title='index.html'
|
|
<script>
|
|
window.onmessage = (event) => {
|
|
// event.source === window means the message is coming from the preload
|
|
// script, as opposed to from an <iframe> or other source.
|
|
if (event.source === window && event.data === 'main-world-port') {
|
|
const [ port ] = event.ports
|
|
// Once we have the port, we can communicate directly with the main
|
|
// process.
|
|
port.onmessage = (event) => {
|
|
console.log('from main process:', event.data)
|
|
port.postMessage(event.data.test * 2)
|
|
}
|
|
}
|
|
}
|
|
</script>
|
|
```
|
|
|
|
[context isolation]: context-isolation.md
|
|
[`ipcRenderer.postMessage`]: ../api/ipc-renderer.md#ipcrendererpostmessagechannel-message-transfer
|
|
[`WebContents.postMessage`]: ../api/web-contents.md#contentspostmessagechannel-message-transfer
|
|
[`MessagePortMain`]: ../api/message-port-main.md
|
|
[`MessageChannelMain`]: ../api/message-channel-main.md
|
|
[`MessagePort`]: https://developer.mozilla.org/en-US/docs/Web/API/MessagePort
|
|
[Channel Messaging API]: https://developer.mozilla.org/en-US/docs/Web/API/Channel_Messaging_API
|