// Copyright (c) 2021 Slack Technologies, Inc. // Use of this source code is governed by the MIT license that can be // found in the LICENSE file. #include "shell/common/logging.h" #include #include #include "base/base_switches.h" #include "base/command_line.h" #include "base/environment.h" #include "base/files/file_path.h" #include "base/logging.h" #include "base/path_service.h" #include "base/strings/string_number_conversions.h" #include "chrome/common/chrome_paths.h" #include "content/public/common/content_switches.h" namespace logging { constexpr std::string_view kLogFileName{"ELECTRON_LOG_FILE"}; constexpr std::string_view kElectronEnableLogging{"ELECTRON_ENABLE_LOGGING"}; base::FilePath GetLogFileName(const base::CommandLine& command_line) { std::string filename = command_line.GetSwitchValueASCII(switches::kLogFile); if (filename.empty()) base::Environment::Create()->GetVar(kLogFileName, &filename); if (!filename.empty()) return base::FilePath::FromUTF8Unsafe(filename); const base::FilePath log_filename(FILE_PATH_LITERAL("electron_debug.log")); base::FilePath log_path; if (base::PathService::Get(chrome::DIR_LOGS, &log_path)) { log_path = log_path.Append(log_filename); return log_path; } else { // error with path service, just use some default file somewhere return log_filename; } } namespace { bool HasExplicitLogFile(const base::CommandLine& command_line) { std::string filename = command_line.GetSwitchValueASCII(switches::kLogFile); if (filename.empty()) base::Environment::Create()->GetVar(kLogFileName, &filename); return !filename.empty(); } LoggingDestination DetermineLoggingDestination( const base::CommandLine& command_line, bool is_preinit) { bool enable_logging = false; std::string logging_destination; if (command_line.HasSwitch(::switches::kEnableLogging)) { enable_logging = true; logging_destination = command_line.GetSwitchValueASCII(switches::kEnableLogging); } else { auto env = base::Environment::Create(); if (env->HasVar(kElectronEnableLogging)) { enable_logging = true; env->GetVar(kElectronEnableLogging, &logging_destination); } } if (!enable_logging) return LOG_NONE; bool also_log_to_stderr = false; #if !defined(NDEBUG) std::string also_log_to_stderr_str; if (base::Environment::Create()->GetVar("ELECTRON_ALSO_LOG_TO_STDERR", &also_log_to_stderr_str) && !also_log_to_stderr_str.empty()) also_log_to_stderr = true; #endif // --enable-logging logs to stderr, --enable-logging=file logs to a file. // NB. this differs from Chromium, in which --enable-logging logs to a file // and --enable-logging=stderr logs to stderr, because that's how Electron // used to work, so in order to not break anyone who was depending on // --enable-logging logging to stderr, we preserve the old behavior by // default. // If --log-file or ELECTRON_LOG_FILE is specified along with // --enable-logging, return LOG_TO_FILE. // If we're in the pre-init phase, before JS has run, we want to avoid // logging to the default log file, which is inside the user data directory, // because we aren't able to accurately determine the user data directory // before JS runs. Instead, log to stderr unless there's an explicit filename // given. if (HasExplicitLogFile(command_line) || (logging_destination == "file" && !is_preinit)) return LOG_TO_FILE | (also_log_to_stderr ? LOG_TO_STDERR : 0); return LOG_TO_SYSTEM_DEBUG_LOG | LOG_TO_STDERR; } } // namespace void InitElectronLogging(const base::CommandLine& command_line, bool is_preinit) { const std::string process_type = command_line.GetSwitchValueASCII(::switches::kProcessType); LoggingDestination logging_dest = DetermineLoggingDestination(command_line, is_preinit); LogLockingState log_locking_state = LOCK_LOG_FILE; base::FilePath log_path; if (command_line.HasSwitch(::switches::kLoggingLevel) && GetMinLogLevel() >= 0) { std::string log_level = command_line.GetSwitchValueASCII(::switches::kLoggingLevel); int level = 0; if (base::StringToInt(log_level, &level) && level >= 0 && level < LOGGING_NUM_SEVERITIES) { SetMinLogLevel(level); } else { DLOG(WARNING) << "Bad log level: " << log_level; } } // Don't resolve the log path unless we need to. Otherwise we leave an open // ALPC handle after sandbox lockdown on Windows. if ((logging_dest & LOG_TO_FILE) != 0) { log_path = GetLogFileName(command_line); } else { log_locking_state = DONT_LOCK_LOG_FILE; } // On Windows, having non canonical forward slashes in log file name causes // problems with sandbox filters, see https://crbug.com/859676 log_path = log_path.NormalizePathSeparators(); LoggingSettings settings; settings.logging_dest = logging_dest; settings.log_file_path = log_path.value().c_str(); settings.lock_log = log_locking_state; // If we're logging to an explicit file passed with --log-file, we don't want // to delete the log file on our second initialization. settings.delete_old = process_type.empty() && (is_preinit || !HasExplicitLogFile(command_line)) ? DELETE_OLD_LOG_FILE : APPEND_TO_OLD_LOG_FILE; bool success = InitLogging(settings); if (!success) { PLOG(ERROR) << "Failed to init logging"; } SetLogItems(true /* pid */, false, true /* timestamp */, false); } } // namespace logging