pmaports/device/testing/device-samsung-manta
Alexandre Marquet b9536f2889
device-samsung-manta: use max77686 RTC (MR 4783)
hwclock default configuration is to use the S3C RTC, which is mapped to
/dev/rtc0. However, reading from this clock fails with the following
kernel message:
"s3c-rtc 101e0000.rtc: hctosys: unable to read the hardware clock"
and the time as boot is then always set to 1/1/1970.

This commit change the default RTC to the MAX77686 one (mapped to
/dev/rtc1), that does not suffer from this issue.

Signed-off-by: Alexandre Marquet <tb@a-marquet.fr>
2024-02-09 18:33:03 +02:00
..
100-wlan-mac.rules device-samsung-manta: switch to mainline kernel (MR 4406) 2023-10-23 08:18:26 +02:00
APKBUILD device-samsung-manta: use max77686 RTC (MR 4783) 2024-02-09 18:33:03 +02:00
deviceinfo samsung-manta: enable automatic kernel upgrades (MR 4780) 2024-01-31 20:38:41 +03:00
hwclock device-samsung-manta: use max77686 RTC (MR 4783) 2024-02-09 18:33:03 +02:00
modules-initfs samsung-manta: add initramfs modules (MR 4780) 2024-01-31 20:38:44 +03:00
networkmanager.conf device-samsung-manta: switch to mainline kernel (MR 4406) 2023-10-23 08:18:26 +02:00
wifi-macaddr.sh device-samsung-manta: make wifi-macaddr.sh pass shellcheck (MR 4783) 2024-02-09 18:33:02 +02:00