platform/x86: pmc_atom: Add Siemens CONNECT X300 to critclk_systems DMI table
commite8796c6c69upstream. The CONNECT X300 uses the PMC clock for on-board components and gets stuck during boot if the clock is disabled. Therefore, add this device to the critical systems list. Tested on CONNECT X300. Fixes:648e921888("clk: x86: Stop marking clocks as CLK_IS_CRITICAL") Signed-off-by: Michael Haener <michael.haener@siemens.com> Signed-off-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
parent
e1ceceb494
commit
b1ecf978fa
1 changed files with 8 additions and 0 deletions
|
|
@ -452,6 +452,14 @@ static const struct dmi_system_id critclk_systems[] = {
|
|||
DMI_MATCH(DMI_PRODUCT_VERSION, "6ES7647-8B"),
|
||||
},
|
||||
},
|
||||
{
|
||||
.ident = "CONNECT X300",
|
||||
.matches = {
|
||||
DMI_MATCH(DMI_SYS_VENDOR, "SIEMENS AG"),
|
||||
DMI_MATCH(DMI_PRODUCT_VERSION, "A5E45074588"),
|
||||
},
|
||||
},
|
||||
|
||||
{ /*sentinel*/ }
|
||||
};
|
||||
|
||||
|
|
|
|||
Loading…