net: hns: Fix loopback test failed at copper ports

[ Upstream commit 2e1f164861 ]

When doing a loopback test at copper ports, the serdes loopback
and the phy loopback will fail, because of the adjust link had
not finished, and phy not ready.

Adds sleep between adjust link and test process to fix it.

Signed-off-by: Yonglong Liu <liuyonglong@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Signed-off-by: Sasha Levin <sashal@kernel.org>
This commit is contained in:
Yonglong Liu 2019-05-31 16:59:50 +08:00 committed by Greg Kroah-Hartman
commit 6bf97a6cb6

View file

@ -339,6 +339,7 @@ static int __lb_setup(struct net_device *ndev,
static int __lb_up(struct net_device *ndev,
enum hnae_loop loop_mode)
{
#define NIC_LB_TEST_WAIT_PHY_LINK_TIME 300
struct hns_nic_priv *priv = netdev_priv(ndev);
struct hnae_handle *h = priv->ae_handle;
int speed, duplex;
@ -365,6 +366,9 @@ static int __lb_up(struct net_device *ndev,
h->dev->ops->adjust_link(h, speed, duplex);
/* wait adjust link done and phy ready */
msleep(NIC_LB_TEST_WAIT_PHY_LINK_TIME);
return 0;
}