We've never seen any device supported by the lm78 or w83781d driver at addresses 0x20-0x27, so let's stop probing these addresses. Extra probes cost time, and have potential for confusing or misdetecting other I2C devices. Signed-off-by: Jean Delvare <khali@linux-fr.org> Signed-off-by: Mark M. Hoffman <mhoffman@lightlink.com>
		
			
				
	
	
		
			67 lines
		
	
	
	
		
			3.1 KiB
			
		
	
	
	
		
			Text
		
	
	
	
	
	
			
		
		
	
	
			67 lines
		
	
	
	
		
			3.1 KiB
			
		
	
	
	
		
			Text
		
	
	
	
	
	
Kernel driver lm78
 | 
						|
==================
 | 
						|
 | 
						|
Supported chips:
 | 
						|
  * National Semiconductor LM78 / LM78-J
 | 
						|
    Prefix: 'lm78'
 | 
						|
    Addresses scanned: I2C 0x28 - 0x2f, ISA 0x290 (8 I/O ports)
 | 
						|
    Datasheet: Publicly available at the National Semiconductor website
 | 
						|
               http://www.national.com/
 | 
						|
  * National Semiconductor LM79
 | 
						|
    Prefix: 'lm79'
 | 
						|
    Addresses scanned: I2C 0x28 - 0x2f, ISA 0x290 (8 I/O ports)
 | 
						|
    Datasheet: Publicly available at the National Semiconductor website
 | 
						|
               http://www.national.com/
 | 
						|
 | 
						|
Author: Frodo Looijaard <frodol@dds.nl>
 | 
						|
 | 
						|
Description
 | 
						|
-----------
 | 
						|
 | 
						|
This driver implements support for the National Semiconductor LM78, LM78-J
 | 
						|
and LM79. They are described as 'Microprocessor System Hardware Monitors'.
 | 
						|
 | 
						|
There is almost no difference between the three supported chips. Functionally,
 | 
						|
the LM78 and LM78-J are exactly identical. The LM79 has one more VID line,
 | 
						|
which is used to report the lower voltages newer Pentium processors use.
 | 
						|
From here on, LM7* means either of these three types.
 | 
						|
 | 
						|
The LM7* implements one temperature sensor, three fan rotation speed sensors,
 | 
						|
seven voltage sensors, VID lines, alarms, and some miscellaneous stuff.
 | 
						|
 | 
						|
Temperatures are measured in degrees Celsius. An alarm is triggered once
 | 
						|
when the Overtemperature Shutdown limit is crossed; it is triggered again
 | 
						|
as soon as it drops below the Hysteresis value. A more useful behavior
 | 
						|
can be found by setting the Hysteresis value to +127 degrees Celsius; in
 | 
						|
this case, alarms are issued during all the time when the actual temperature
 | 
						|
is above the Overtemperature Shutdown value. Measurements are guaranteed
 | 
						|
between -55 and +125 degrees, with a resolution of 1 degree.
 | 
						|
 | 
						|
Fan rotation speeds are reported in RPM (rotations per minute). An alarm is
 | 
						|
triggered if the rotation speed has dropped below a programmable limit. Fan
 | 
						|
readings can be divided by a programmable divider (1, 2, 4 or 8) to give
 | 
						|
the readings more range or accuracy. Not all RPM values can accurately be
 | 
						|
represented, so some rounding is done. With a divider of 2, the lowest
 | 
						|
representable value is around 2600 RPM.
 | 
						|
 | 
						|
Voltage sensors (also known as IN sensors) report their values in volts.
 | 
						|
An alarm is triggered if the voltage has crossed a programmable minimum
 | 
						|
or maximum limit. Note that minimum in this case always means 'closest to
 | 
						|
zero'; this is important for negative voltage measurements. All voltage
 | 
						|
inputs can measure voltages between 0 and 4.08 volts, with a resolution
 | 
						|
of 0.016 volt.
 | 
						|
 | 
						|
The VID lines encode the core voltage value: the voltage level your processor
 | 
						|
should work with. This is hardcoded by the mainboard and/or processor itself.
 | 
						|
It is a value in volts. When it is unconnected, you will often find the
 | 
						|
value 3.50 V here.
 | 
						|
 | 
						|
If an alarm triggers, it will remain triggered until the hardware register
 | 
						|
is read at least once. This means that the cause for the alarm may
 | 
						|
already have disappeared! Note that in the current implementation, all
 | 
						|
hardware registers are read whenever any data is read (unless it is less
 | 
						|
than 1.5 seconds since the last update). This means that you can easily
 | 
						|
miss once-only alarms.
 | 
						|
 | 
						|
The LM7* only updates its values each 1.5 seconds; reading it more often
 | 
						|
will do no harm, but will return 'old' values.
 |