 7ab83a9137
			
		
	
	
	7ab83a9137
	
	
	
		
			
			This patch adds a new ID to the SMSC LPC47B397-NC hardware monitoring driver - for a chip that is claimed to be 100% compatible otherwise. Signed-off-by: Bryan Young (Utilitek Systems, Inc.) Signed-off-by: Mark M. Hoffman <mhoffman@lightlink.com> Signed-off-by: Jean Delvare <khali@linux-fr.org> Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
		
			
				
	
	
		
			162 lines
		
	
	
	
		
			4.4 KiB
			
		
	
	
	
		
			Text
		
	
	
	
	
	
			
		
		
	
	
			162 lines
		
	
	
	
		
			4.4 KiB
			
		
	
	
	
		
			Text
		
	
	
	
	
	
| Kernel driver smsc47b397
 | |
| ========================
 | |
| 
 | |
| Supported chips:
 | |
|   * SMSC LPC47B397-NC
 | |
|   * SMSC SCH5307-NS
 | |
|     Prefix: 'smsc47b397'
 | |
|     Addresses scanned: none, address read from Super I/O config space
 | |
|     Datasheet: In this file
 | |
| 
 | |
| Authors: Mark M. Hoffman <mhoffman@lightlink.com>
 | |
|          Utilitek Systems, Inc.
 | |
| 
 | |
| November 23, 2004
 | |
| 
 | |
| The following specification describes the SMSC LPC47B397-NC[1] sensor chip
 | |
| (for which there is no public datasheet available). This document was
 | |
| provided by Craig Kelly (In-Store Broadcast Network) and edited/corrected
 | |
| by Mark M. Hoffman <mhoffman@lightlink.com>.
 | |
| 
 | |
| [1] And SMSC SCH5307-NS, which has a different device ID but is otherwise
 | |
| compatible.
 | |
| 
 | |
| * * * * *
 | |
| 
 | |
| Methods for detecting the HP SIO and reading the thermal data on a dc7100.
 | |
| 
 | |
| The thermal information on the dc7100 is contained in the SIO Hardware Monitor
 | |
| (HWM). The information is accessed through an index/data pair. The index/data
 | |
| pair is located at the HWM Base Address + 0 and the HWM Base Address + 1. The
 | |
| HWM Base address can be obtained from Logical Device 8, registers 0x60 (MSB)
 | |
| and 0x61 (LSB). Currently we are using 0x480 for the HWM Base Address and
 | |
| 0x480 and 0x481 for the index/data pair.
 | |
| 
 | |
| Reading temperature information.
 | |
| The temperature information is located in the following registers:
 | |
| Temp1		0x25	(Currently, this reflects the CPU temp on all systems).
 | |
| Temp2		0x26
 | |
| Temp3		0x27
 | |
| Temp4		0x80
 | |
| 
 | |
| Programming Example
 | |
| The following is an example of how to read the HWM temperature registers:
 | |
| MOV	DX,480H
 | |
| MOV	AX,25H
 | |
| OUT	DX,AL
 | |
| MOV	DX,481H
 | |
| IN	AL,DX
 | |
| 
 | |
| AL contains the data in hex, the temperature in Celsius is the decimal
 | |
| equivalent.
 | |
| 
 | |
| Ex: If AL contains 0x2A, the temperature is 42 degrees C.
 | |
| 
 | |
| Reading tach information.
 | |
| The fan speed information is located in the following registers:
 | |
| 		LSB	MSB
 | |
| Tach1		0x28	0x29	(Currently, this reflects the CPU
 | |
| 				fan speed on all systems).
 | |
| Tach2		0x2A	0x2B
 | |
| Tach3		0x2C	0x2D
 | |
| Tach4		0x2E	0x2F
 | |
| 
 | |
| Important!!!
 | |
| Reading the tach LSB locks the tach MSB.
 | |
| The LSB Must be read first.
 | |
| 
 | |
| How to convert the tach reading to RPM.
 | |
| The tach reading (TCount) is given by: (Tach MSB * 256) + (Tach LSB)
 | |
| The SIO counts the number of 90kHz (11.111us) pulses per revolution.
 | |
| RPM = 60/(TCount * 11.111us)
 | |
| 
 | |
| Example:
 | |
| Reg 0x28 = 0x9B
 | |
| Reg 0x29 = 0x08
 | |
| 
 | |
| TCount = 0x89B = 2203
 | |
| 
 | |
| RPM = 60 / (2203 * 11.11111 E-6) = 2451 RPM
 | |
| 
 | |
| Obtaining the SIO version.
 | |
| 
 | |
| CONFIGURATION SEQUENCE
 | |
| To program the configuration registers, the following sequence must be followed:
 | |
| 1. Enter Configuration Mode
 | |
| 2. Configure the Configuration Registers
 | |
| 3. Exit Configuration Mode.
 | |
| 
 | |
| Enter Configuration Mode
 | |
| To place the chip into the Configuration State The config key (0x55) is written
 | |
| to the CONFIG PORT (0x2E).
 | |
| 
 | |
| Configuration Mode
 | |
| In configuration mode, the INDEX PORT is located at the CONFIG PORT address and
 | |
| the DATA PORT is at INDEX PORT address + 1.
 | |
| 
 | |
| The desired configuration registers are accessed in two steps:
 | |
| a.	Write the index of the Logical Device Number Configuration Register
 | |
| 	(i.e., 0x07) to the INDEX PORT and then write the number of the
 | |
| 	desired logical device to the DATA PORT.
 | |
| 
 | |
| b.	Write the address of the desired configuration register within the
 | |
| 	logical device to the INDEX PORT and then write or read the config-
 | |
| 	uration register through the DATA PORT.
 | |
| 
 | |
| Note: If accessing the Global Configuration Registers, step (a) is not required.
 | |
| 
 | |
| Exit Configuration Mode
 | |
| To exit the Configuration State the write 0xAA to the CONFIG PORT (0x2E).
 | |
| The chip returns to the RUN State.  (This is important).
 | |
| 
 | |
| Programming Example
 | |
| The following is an example of how to read the SIO Device ID located at 0x20
 | |
| 
 | |
| ; ENTER CONFIGURATION MODE
 | |
| MOV	DX,02EH
 | |
| MOV	AX,055H
 | |
| OUT	DX,AL
 | |
| ; GLOBAL CONFIGURATION  REGISTER
 | |
| MOV	DX,02EH
 | |
| MOV	AL,20H
 | |
| OUT	DX,AL
 | |
| ; READ THE DATA
 | |
| MOV	DX,02FH
 | |
| IN	AL,DX
 | |
| ; EXIT CONFIGURATION MODE
 | |
| MOV	DX,02EH
 | |
| MOV	AX,0AAH
 | |
| OUT	DX,AL
 | |
| 
 | |
| The registers of interest for identifying the SIO on the dc7100 are Device ID
 | |
| (0x20) and Device Rev  (0x21).
 | |
| 
 | |
| The Device ID will read 0x6F (for SCH5307-NS, 0x81)
 | |
| The Device Rev currently reads 0x01
 | |
| 
 | |
| Obtaining the HWM Base Address.
 | |
| The following is an example of how to read the HWM Base Address located in
 | |
| Logical Device 8.
 | |
| 
 | |
| ; ENTER CONFIGURATION MODE
 | |
| MOV	DX,02EH
 | |
| MOV	AX,055H
 | |
| OUT	DX,AL
 | |
| ; CONFIGURE REGISTER CRE0,
 | |
| ; LOGICAL DEVICE 8
 | |
| MOV	DX,02EH
 | |
| MOV	AL,07H
 | |
| OUT	DX,AL ;Point to LD# Config Reg
 | |
| MOV	DX,02FH
 | |
| MOV	AL, 08H
 | |
| OUT	DX,AL;Point to Logical Device 8
 | |
| ;
 | |
| MOV	DX,02EH
 | |
| MOV	AL,60H
 | |
| OUT	DX,AL	; Point to HWM Base Addr MSB
 | |
| MOV	DX,02FH
 | |
| IN	AL,DX	; Get MSB of HWM Base Addr
 | |
| ; EXIT CONFIGURATION MODE
 | |
| MOV	DX,02EH
 | |
| MOV	AX,0AAH
 | |
| OUT	DX,AL
 |