| Kernel driver max16064
 | |
| ======================
 | |
| 
 | |
| Supported chips:
 | |
|   * Maxim MAX16064
 | |
|     Prefix: 'max16064'
 | |
|     Addresses scanned: -
 | |
|     Datasheet: http://datasheets.maxim-ic.com/en/ds/MAX16064.pdf
 | |
| 
 | |
| Author: Guenter Roeck <linux@roeck-us.net>
 | |
| 
 | |
| 
 | |
| Description
 | |
| -----------
 | |
| 
 | |
| This driver supports hardware montoring for Maxim MAX16064 Quad Power-Supply
 | |
| Controller with Active-Voltage Output Control and PMBus Interface.
 | |
| 
 | |
| The driver is a client driver to the core PMBus driver.
 | |
| Please see Documentation/hwmon/pmbus for details on PMBus client drivers.
 | |
| 
 | |
| 
 | |
| Usage Notes
 | |
| -----------
 | |
| 
 | |
| This driver does not auto-detect devices. You will have to instantiate the
 | |
| devices explicitly. Please see Documentation/i2c/instantiating-devices for
 | |
| details.
 | |
| 
 | |
| 
 | |
| Platform data support
 | |
| ---------------------
 | |
| 
 | |
| The driver supports standard PMBus driver platform data.
 | |
| 
 | |
| 
 | |
| Sysfs entries
 | |
| -------------
 | |
| 
 | |
| The following attributes are supported. Limits are read-write; all other
 | |
| attributes are read-only.
 | |
| 
 | |
| in[1-4]_label		"vout[1-4]"
 | |
| in[1-4]_input		Measured voltage. From READ_VOUT register.
 | |
| in[1-4]_min		Minimum Voltage. From VOUT_UV_WARN_LIMIT register.
 | |
| in[1-4]_max		Maximum voltage. From VOUT_OV_WARN_LIMIT register.
 | |
| in[1-4]_lcrit		Critical minimum Voltage. VOUT_UV_FAULT_LIMIT register.
 | |
| in[1-4]_crit		Critical maximum voltage. From VOUT_OV_FAULT_LIMIT register.
 | |
| in[1-4]_min_alarm	Voltage low alarm. From VOLTAGE_UV_WARNING status.
 | |
| in[1-4]_max_alarm	Voltage high alarm. From VOLTAGE_OV_WARNING status.
 | |
| in[1-4]_lcrit_alarm	Voltage critical low alarm. From VOLTAGE_UV_FAULT status.
 | |
| in[1-4]_crit_alarm	Voltage critical high alarm. From VOLTAGE_OV_FAULT status.
 | |
| in[1-4]_highest		Historical maximum voltage.
 | |
| in[1-4]_reset_history	Write any value to reset history.
 | |
| 
 | |
| temp1_input		Measured temperature. From READ_TEMPERATURE_1 register.
 | |
| temp1_max		Maximum temperature. From OT_WARN_LIMIT register.
 | |
| temp1_crit		Critical high temperature. From OT_FAULT_LIMIT register.
 | |
| temp1_max_alarm		Chip temperature high alarm. Set by comparing
 | |
| 			READ_TEMPERATURE_1 with OT_WARN_LIMIT if TEMP_OT_WARNING
 | |
| 			status is set.
 | |
| temp1_crit_alarm	Chip temperature critical high alarm. Set by comparing
 | |
| 			READ_TEMPERATURE_1 with OT_FAULT_LIMIT if TEMP_OT_FAULT
 | |
| 			status is set.
 | |
| temp1_highest		Historical maximum temperature.
 | |
| temp1_reset_history	Write any value to reset history.
 |