Commit graph

3 commits

Author SHA1 Message Date
Greg Ungerer
66d857b08b m68k: merge m68k and m68knommu arch directories
There is a lot of common code that could be shared between the m68k
and m68knommu arch branches. It makes sense to merge the two branches
into a single directory structure so that we can more easily share
that common code.

This is a brute force merge, based on a script from Stephen King
<sfking@fdwdc.com>, which was originally written by Arnd Bergmann
<arnd@arndb.de>.

> The script was inspired by the script Sam Ravnborg used to merge the
> includes from m68knommu. For those files common to both arches but
> differing in content, the m68k version of the file is renamed to
> <file>_mm.<ext> and the m68knommu version of the file is moved into the
> corresponding m68k directory and renamed <file>_no.<ext> and a small
> wrapper file <file>.<ext> is used to select between the two version. Files
> that are common to both but don't differ are removed from the m68knommu
> tree and files and directories that are unique to the m68knommu tree are
> moved to the m68k tree. Finally, the arch/m68knommu tree is removed.
>
> To select between the the versions of the files, the wrapper uses
>
> #ifdef CONFIG_MMU
> #include <file>_mm.<ext>
> #else
> #include <file>_no.<ext>
> #endif

On top of this file merge I have done a simplistic merge of m68k and
m68knommu Kconfig, which primarily attempts to keep existing options and
menus in place. Other than a handful of options being moved it produces
identical .config outputs on m68k and m68knommu targets I tested it on.

With this in place there is now quite a bit of scope for merge cleanups
in future patches.

Signed-off-by: Greg Ungerer <gerg@uclinux.org>
2011-03-25 14:05:13 +10:00
Greg Ungerer
babc08b7e9 m68knommu: move ColdFire DMA register addresses to per-cpu headers
The base addresses of the ColdFire DMA unit registers belong with
all the other address definitions in the per-cpu headers. The current
definitions assume they are relative to an MBAR register. Not all
ColdFire CPUs have an MBAR register. A clean address define can only
be acheived in the per-cpu headers along with all the other chips
peripheral base addresses.

Signed-off-by: Greg Ungerer <gerg@uclinux.org>
2011-03-15 21:01:54 +10:00
Greg Ungerer
dad263b84e m68knommu: create common DMA table for ColdFire CPUs
Move the ColdFire DMA address table into its own file, and out
of each of the different CPU config files. No need to have a copy
of it in each of the config setup files.

Signed-off-by: Greg Ungerer <gerg@uclinux.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2008-02-01 21:00:01 +11:00