regulator: Don't warn on omitted voltage constraints
Specifying voltage constraints is optional (and only needed if the consumer is allowed to change the voltage) so don't complain unless a voltage has been specified. Also avoid surprises with a dangling else while we're here. Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
This commit is contained in:
parent
216765d92a
commit
3e2b9abda5
1 changed files with 5 additions and 1 deletions
|
@ -709,8 +709,12 @@ static int set_machine_constraints(struct regulator_dev *rdev,
|
||||||
cmax = INT_MAX;
|
cmax = INT_MAX;
|
||||||
}
|
}
|
||||||
|
|
||||||
|
/* voltage constraints are optional */
|
||||||
|
if ((cmin == 0) && (cmax == 0))
|
||||||
|
goto out;
|
||||||
|
|
||||||
/* else require explicit machine-level constraints */
|
/* else require explicit machine-level constraints */
|
||||||
else if (cmin <= 0 || cmax <= 0 || cmax < cmin) {
|
if (cmin <= 0 || cmax <= 0 || cmax < cmin) {
|
||||||
pr_err("%s: %s '%s' voltage constraints\n",
|
pr_err("%s: %s '%s' voltage constraints\n",
|
||||||
__func__, "invalid", name);
|
__func__, "invalid", name);
|
||||||
ret = -EINVAL;
|
ret = -EINVAL;
|
||||||
|
|