											2009-07-28 15:52:22 +01:00
										 |  |  | Kernel driver wm831x-hwmon | 
					
						
							|  |  |  | ========================== | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Supported chips: | 
					
						
							|  |  |  |   * Wolfson Microelectronics WM831x PMICs | 
					
						
							|  |  |  |     Prefix: 'wm831x' | 
					
						
							|  |  |  |     Datasheet: | 
					
						
							|  |  |  | 	http://www.wolfsonmicro.com/products/WM8310 | 
					
						
							|  |  |  | 	http://www.wolfsonmicro.com/products/WM8311 | 
					
						
							|  |  |  | 	http://www.wolfsonmicro.com/products/WM8312 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Authors: Mark Brown <broonie@opensource.wolfsonmicro.com> | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Description | 
					
						
							|  |  |  | ----------- | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | The WM831x series of PMICs include an AUXADC which can be used to | 
					
						
							|  |  |  | monitor a range of system operating parameters, including the voltages | 
					
						
							|  |  |  | of the major supplies within the system.  Currently the driver provides | 
					
						
							|  |  |  | reporting of all the input values but does not provide any alarms. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Voltage Monitoring | 
					
						
							|  |  |  | ------------------ | 
					
						
							|  |  |  | 
 | 
					
						
							| 
									
										
										
										
											2012-02-17 17:46:21 +01:00
										 |  |  | Voltages are sampled by a 12 bit ADC.  Voltages in millivolts are 1.465 | 
					
						
							| 
									
										
										
										
											2009-07-28 15:52:22 +01:00
										 |  |  | times the ADC value. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Temperature Monitoring | 
					
						
							|  |  |  | ---------------------- | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Temperatures are sampled by a 12 bit ADC.  Chip and battery temperatures | 
					
						
							|  |  |  | are available.  The chip temperature is calculated as: | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | 	Degrees celsius = (512.18 - data) / 1.0983 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | while the battery temperature calculation will depend on the NTC | 
					
						
							|  |  |  | thermistor component. |