								Generic Thermal Sysfs driver How To
							 | 
						
					
						
							
								
									
										
										
										
											2009-10-26 08:38:59 +01:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								===================================
							 | 
						
					
						
							
								
									
										
										
										
											2008-01-17 15:51:08 +08:00
										 
									 
								 
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								Written by Sujith Thomas <sujith.thomas@intel.com>, Zhang Rui <rui.zhang@intel.com>
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								Updated: 2 January 2008
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								Copyright (c)  2008 Intel Corporation
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								0. Introduction
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							
								
									
										
										
										
											2009-10-26 08:38:59 +01:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								The generic thermal sysfs provides a set of interfaces for thermal zone
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								devices (sensors) and thermal cooling devices (fan, processor...) to register
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								with the thermal management solution and to be a part of it.
							 | 
						
					
						
							
								
									
										
										
										
											2008-01-17 15:51:08 +08:00
										 
									 
								 
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							
								
									
										
										
										
											2009-10-26 08:38:59 +01:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								This how-to focuses on enabling new thermal zone and cooling devices to
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								participate in thermal management.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								This solution is platform independent and any type of thermal zone devices
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								and cooling devices should be able to make use of the infrastructure.
							 | 
						
					
						
							
								
									
										
										
										
											2008-01-17 15:51:08 +08:00
										 
									 
								 
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							
								
									
										
										
										
											2009-10-26 08:38:59 +01:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								The main task of the thermal sysfs driver is to expose thermal zone attributes
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								as well as cooling device attributes to the user space.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								An intelligent thermal management application can make decisions based on
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								inputs from thermal zone attributes (the current temperature and trip point
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								temperature) and throttle appropriate devices.
							 | 
						
					
						
							
								
									
										
										
										
											2008-01-17 15:51:08 +08:00
										 
									 
								 
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								[0-*]	denotes any positive number starting from 0
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								[1-*]	denotes any positive number starting from 1
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								1. thermal sysfs driver interface functions
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								1.1 thermal zone device interface
							 | 
						
					
						
							
								
									
										
										
										
											2009-10-26 08:38:59 +01:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								1.1.1 struct thermal_zone_device *thermal_zone_device_register(char *name,
							 | 
						
					
						
							
								
									
										
										
										
											2012-07-25 10:10:58 +08:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
										int trips, int mask, void *devdata,
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
										struct thermal_zone_device_ops *ops)
							 | 
						
					
						
							
								
									
										
										
										
											2009-10-26 08:38:59 +01:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    This interface function adds a new thermal zone device (sensor) to
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    /sys/class/thermal folder as thermal_zone[0-*]. It tries to bind all the
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    thermal cooling devices registered at the same time.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    name: the thermal zone name.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    trips: the total number of trip points this thermal zone supports.
							 | 
						
					
						
							
								
									
										
										
										
											2012-07-25 10:10:58 +08:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								    mask: Bit string: If 'n'th bit is set, then trip point 'n' is writeable.
							 | 
						
					
						
							
								
									
										
										
										
											2009-10-26 08:38:59 +01:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								    devdata: device private data
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    ops: thermal zone device call-backs.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									.bind: bind the thermal zone device with a thermal cooling device.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									.unbind: unbind the thermal zone device with a thermal cooling device.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									.get_temp: get the current temperature of the thermal zone.
							 | 
						
					
						
							
								
									
										
										
										
											2012-07-25 10:11:00 +08:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
									.get_mode: get the current mode (enabled/disabled) of the thermal zone.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									    - "enabled" means the kernel thermal management is enabled.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									    - "disabled" will prevent kernel thermal driver action upon trip points
							 | 
						
					
						
							
								
									
										
										
										
											2009-10-26 08:38:59 +01:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
									      so that user applications can take charge of thermal management.
							 | 
						
					
						
							
								
									
										
										
										
											2012-07-25 10:11:00 +08:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
									.set_mode: set the mode (enabled/disabled) of the thermal zone.
							 | 
						
					
						
							
								
									
										
										
										
											2009-10-26 08:38:59 +01:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
									.get_trip_type: get the type of certain trip point.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									.get_trip_temp: get the temperature above which the certain trip point
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
											will be fired.
							 | 
						
					
						
							
								
									
										
										
										
											2008-01-17 15:51:08 +08:00
										 
									 
								 
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								1.1.2 void thermal_zone_device_unregister(struct thermal_zone_device *tz)
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							
								
									
										
										
										
											2009-10-26 08:38:59 +01:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								    This interface function removes the thermal zone device.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    It deletes the corresponding entry form /sys/class/thermal folder and
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    unbind all the thermal cooling devices it uses.
							 | 
						
					
						
							
								
									
										
										
										
											2008-01-17 15:51:08 +08:00
										 
									 
								 
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								1.2 thermal cooling device interface
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								1.2.1 struct thermal_cooling_device *thermal_cooling_device_register(char *name,
							 | 
						
					
						
							
								
									
										
										
										
											2009-10-26 08:38:59 +01:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
										void *devdata, struct thermal_cooling_device_ops *)
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    This interface function adds a new thermal cooling device (fan/processor/...)
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    to /sys/class/thermal/ folder as cooling_device[0-*]. It tries to bind itself
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    to all the thermal zone devices register at the same time.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    name: the cooling device name.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    devdata: device private data.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    ops: thermal cooling devices call-backs.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									.get_max_state: get the Maximum throttle state of the cooling device.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									.get_cur_state: get the Current throttle state of the cooling device.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									.set_cur_state: set the Current throttle state of the cooling device.
							 | 
						
					
						
							
								
									
										
										
										
											2008-01-17 15:51:08 +08:00
										 
									 
								 
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								1.2.2 void thermal_cooling_device_unregister(struct thermal_cooling_device *cdev)
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							
								
									
										
										
										
											2009-10-26 08:38:59 +01:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								    This interface function remove the thermal cooling device.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    It deletes the corresponding entry form /sys/class/thermal folder and
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    unbind itself from all the thermal zone devices using it.
							 | 
						
					
						
							
								
									
										
										
										
											2008-01-17 15:51:08 +08:00
										 
									 
								 
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								1.3 interface for binding a thermal zone device with a thermal cooling device
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								1.3.1 int thermal_zone_bind_cooling_device(struct thermal_zone_device *tz,
							 | 
						
					
						
							
								
									
										
										
										
											2012-06-26 16:35:57 +08:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
									int trip, struct thermal_cooling_device *cdev,
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									unsigned long upper, unsigned long lower);
							 | 
						
					
						
							
								
									
										
										
										
											2008-01-17 15:51:08 +08:00
										 
									 
								 
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							
								
									
										
										
										
											2009-10-26 08:38:59 +01:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								    This interface function bind a thermal cooling device to the certain trip
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    point of a thermal zone device.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    This function is usually called in the thermal zone device .bind callback.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    tz: the thermal zone device
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    cdev: thermal cooling device
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    trip: indicates which trip point the cooling devices is associated with
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									  in this thermal zone.
							 | 
						
					
						
							
								
									
										
										
										
											2012-06-26 16:35:57 +08:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								    upper:the Maximum cooling state for this trip point.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								          THERMAL_NO_LIMIT means no upper limit,
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									  and the cooling device can be in max_state.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    lower:the Minimum cooling state can be used for this trip point.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								          THERMAL_NO_LIMIT means no lower limit,
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									  and the cooling device can be in cooling state 0.
							 | 
						
					
						
							
								
									
										
										
										
											2008-01-17 15:51:08 +08:00
										 
									 
								 
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								1.3.2 int thermal_zone_unbind_cooling_device(struct thermal_zone_device *tz,
							 | 
						
					
						
							
								
									
										
										
										
											2009-10-26 08:38:59 +01:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
										int trip, struct thermal_cooling_device *cdev);
							 | 
						
					
						
							
								
									
										
										
										
											2008-01-17 15:51:08 +08:00
										 
									 
								 
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							
								
									
										
										
										
											2009-10-26 08:38:59 +01:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								    This interface function unbind a thermal cooling device from the certain
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    trip point of a thermal zone device. This function is usually called in
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    the thermal zone device .unbind callback.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    tz: the thermal zone device
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    cdev: thermal cooling device
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    trip: indicates which trip point the cooling devices is associated with
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									  in this thermal zone.
							 | 
						
					
						
							
								
									
										
										
										
											2008-01-17 15:51:08 +08:00
										 
									 
								 
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							
								
									
										
										
										
											2012-09-18 11:05:06 +05:30
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								1.4 Thermal Zone Parameters
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								1.4.1 struct thermal_bind_params
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    This structure defines the following parameters that are used to bind
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    a zone with a cooling device for a particular trip point.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    .cdev: The cooling device pointer
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    .weight: The 'influence' of a particular cooling device on this zone.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								             This is on a percentage scale. The sum of all these weights
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								             (for a particular zone) cannot exceed 100.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    .trip_mask:This is a bit mask that gives the binding relation between
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								               this thermal zone and cdev, for a particular trip point.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								               If nth bit is set, then the cdev and thermal zone are bound
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								               for trip point n.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    .match: This call back returns success(0) if the 'tz and cdev' need to
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									    be bound, as per platform data.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								1.4.2 struct thermal_zone_params
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    This structure defines the platform level parameters for a thermal zone.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    This data, for each thermal zone should come from the platform layer.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    This is an optional feature where some platforms can choose not to
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    provide this data.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    .governor_name: Name of the thermal governor used for this zone
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    .num_tbps: Number of thermal_bind_params entries for this zone
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    .tbp: thermal_bind_params entries
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							
								
									
										
										
										
											2008-01-17 15:51:08 +08:00
										 
									 
								 
							 | 
							
								
							 | 
							
								
							 | 
							
							
								2. sysfs attributes structure
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								RO	read only value
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								RW	read/write value
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							
								
									
										
										
										
											2008-04-22 08:50:09 +08:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								Thermal sysfs attributes will be represented under /sys/class/thermal.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								Hwmon sysfs I/F extension is also available under /sys/class/hwmon
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								if hwmon is compiled in or built as a module.
							 | 
						
					
						
							
								
									
										
										
										
											2008-01-17 15:51:08 +08:00
										 
									 
								 
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								Thermal zone device sys I/F, created once it's registered:
							 | 
						
					
						
							
								
									
										
										
										
											2008-04-22 08:50:09 +08:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								/sys/class/thermal/thermal_zone[0-*]:
							 | 
						
					
						
							
								
									
										
										
										
											2009-10-26 08:38:59 +01:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								    |---type:			Type of the thermal zone
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    |---temp:			Current temperature
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    |---mode:			Working mode of the thermal zone
							 | 
						
					
						
							
								
									
										
										
										
											2012-09-18 11:05:06 +05:30
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								    |---policy:			Thermal governor used for this zone
							 | 
						
					
						
							
								
									
										
										
										
											2009-10-26 08:38:59 +01:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								    |---trip_point_[0-*]_temp:	Trip point temperature
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    |---trip_point_[0-*]_type:	Trip point type
							 | 
						
					
						
							
								
									
										
										
										
											2012-07-25 10:10:59 +08:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								    |---trip_point_[0-*]_hyst:	Hysteresis value for this trip point
							 | 
						
					
						
							
								
									
										
										
										
											2008-01-17 15:51:08 +08:00
										 
									 
								 
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								Thermal cooling device sys I/F, created once it's registered:
							 | 
						
					
						
							
								
									
										
										
										
											2008-04-22 08:50:09 +08:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								/sys/class/thermal/cooling_device[0-*]:
							 | 
						
					
						
							
								
									
										
										
										
											2009-10-26 08:38:59 +01:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								    |---type:			Type of the cooling device(processor/fan/...)
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    |---max_state:		Maximum cooling state of the cooling device
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    |---cur_state:		Current cooling state of the cooling device
							 | 
						
					
						
							
								
									
										
										
										
											2008-01-17 15:51:08 +08:00
										 
									 
								 
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							
								
									
										
										
										
											2009-10-26 08:38:59 +01:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								Then next two dynamic attributes are created/removed in pairs. They represent
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								the relationship between a thermal zone and its associated cooling device.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								They are created/removed for each successful execution of
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								thermal_zone_bind_cooling_device/thermal_zone_unbind_cooling_device.
							 | 
						
					
						
							
								
									
										
										
										
											2008-01-17 15:51:08 +08:00
										 
									 
								 
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							
								
									
										
										
										
											2009-10-26 08:38:59 +01:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								/sys/class/thermal/thermal_zone[0-*]:
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    |---cdev[0-*]:		[0-*]th cooling device in current thermal zone
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    |---cdev[0-*]_trip_point:	Trip point that cdev[0-*] is associated with
							 | 
						
					
						
							
								
									
										
										
										
											2008-01-17 15:51:08 +08:00
										 
									 
								 
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							
								
									
										
										
										
											2008-04-22 08:50:09 +08:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								Besides the thermal zone device sysfs I/F and cooling device sysfs I/F,
							 | 
						
					
						
							
								
									
										
										
										
											2009-10-26 08:38:59 +01:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								the generic thermal driver also creates a hwmon sysfs I/F for each _type_
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								of thermal zone device. E.g. the generic thermal driver registers one hwmon
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								class device and build the associated hwmon sysfs I/F for all the registered
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								ACPI thermal zones.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							
								
									
										
										
										
											2008-04-22 08:50:09 +08:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								/sys/class/hwmon/hwmon[0-*]:
							 | 
						
					
						
							
								
									
										
										
										
											2009-10-26 08:38:59 +01:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								    |---name:			The type of the thermal zone devices
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    |---temp[1-*]_input:	The current temperature of thermal zone [1-*]
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    |---temp[1-*]_critical:	The critical trip point of thermal zone [1-*]
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							
								
									
										
										
										
											2008-04-22 08:50:09 +08:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								Please read Documentation/hwmon/sysfs-interface for additional information.
							 | 
						
					
						
							
								
									
										
										
										
											2008-01-17 15:51:08 +08:00
										 
									 
								 
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								***************************
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								* Thermal zone attributes *
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								***************************
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							
								
									
										
										
										
											2009-10-26 08:38:59 +01:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								type
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									Strings which represent the thermal zone type.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									This is given by thermal zone driver as part of registration.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									E.g: "acpitz" indicates it's an ACPI thermal device.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									In order to keep it consistent with hwmon sys attribute; this should
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									be a short, lowercase string, not containing spaces nor dashes.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									RO, Required
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								temp
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									Current temperature as reported by thermal zone (sensor).
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									Unit: millidegree Celsius
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									RO, Required
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								mode
							 | 
						
					
						
							
								
									
										
										
										
											2012-07-25 10:11:00 +08:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
									One of the predefined values in [enabled, disabled].
							 | 
						
					
						
							
								
									
										
										
										
											2009-10-26 08:38:59 +01:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
									This file gives information about the algorithm that is currently
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									managing the thermal zone. It can be either default kernel based
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									algorithm or user space application.
							 | 
						
					
						
							
								
									
										
										
										
											2012-07-25 10:11:00 +08:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
									enabled		= enable Kernel Thermal management.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									disabled	= Preventing kernel thermal zone driver actions upon
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
											  trip points so that user application can take full
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
											  charge of the thermal management.
							 | 
						
					
						
							
								
									
										
										
										
											2009-10-26 08:38:59 +01:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
									RW, Optional
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							
								
									
										
										
										
											2012-09-18 11:05:06 +05:30
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								policy
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									One of the various thermal governors used for a particular zone.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									RW, Required
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							
								
									
										
										
										
											2009-10-26 08:38:59 +01:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								trip_point_[0-*]_temp
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									The temperature above which trip point will be fired.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									Unit: millidegree Celsius
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									RO, Optional
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								trip_point_[0-*]_type
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									Strings which indicate the type of the trip point.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									E.g. it can be one of critical, hot, passive, active[0-*] for ACPI
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									thermal zone.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									RO, Optional
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							
								
									
										
										
										
											2012-07-25 10:10:59 +08:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								trip_point_[0-*]_hyst
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									The hysteresis value for a trip point, represented as an integer
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									Unit: Celsius
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									RW, Optional
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							
								
									
										
										
										
											2009-10-26 08:38:59 +01:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								cdev[0-*]
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									Sysfs link to the thermal cooling device node where the sys I/F
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									for cooling device throttling control represents.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									RO, Optional
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								cdev[0-*]_trip_point
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									The trip point with which cdev[0-*] is associated in this thermal
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									zone; -1 means the cooling device is not associated with any trip
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									point.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									RO, Optional
							 | 
						
					
						
							
								
									
										
										
										
											2009-10-26 08:39:00 +01:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								passive
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									Attribute is only present for zones in which the passive cooling
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									policy is not supported by native thermal driver. Default is zero
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									and can be set to a temperature (in millidegrees) to enable a
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									passive trip point for the zone. Activation is done by polling with
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									an interval of 1 second.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									Unit: millidegrees Celsius
							 | 
						
					
						
							
								
									
										
										
										
											2009-10-26 08:39:02 +01:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
									Valid values: 0 (disabled) or greater than 1000
							 | 
						
					
						
							
								
									
										
										
										
											2009-10-26 08:39:00 +01:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
									RW, Optional
							 | 
						
					
						
							
								
									
										
										
										
											2009-10-26 08:38:59 +01:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								*****************************
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								* Cooling device attributes *
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								*****************************
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								type
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									String which represents the type of device, e.g:
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									- for generic ACPI: should be "Fan", "Processor" or "LCD"
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									- for memory controller device on intel_menlow platform:
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									  should be "Memory controller".
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									RO, Required
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								max_state
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									The maximum permissible cooling state of this cooling device.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									RO, Required
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								cur_state
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									The current cooling state of this cooling device.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									The value can any integer numbers between 0 and max_state:
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									- cur_state == 0 means no cooling
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									- cur_state == max_state means the maximum cooling.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
									RW, Required
							 | 
						
					
						
							
								
									
										
										
										
											2008-01-17 15:51:08 +08:00
										 
									 
								 
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								3. A simple implementation
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							
								
									
										
										
										
											2009-10-26 08:38:59 +01:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								ACPI thermal zone may support multiple trip points like critical, hot,
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								passive, active. If an ACPI thermal zone supports critical, passive,
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								active[0] and active[1] at the same time, it may register itself as a
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								thermal_zone_device (thermal_zone1) with 4 trip points in all.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								It has one processor and one fan, which are both registered as
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								thermal_cooling_device.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								If the processor is listed in _PSL method, and the fan is listed in _AL0
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								method, the sys I/F structure will be built like this:
							 | 
						
					
						
							
								
									
										
										
										
											2008-01-17 15:51:08 +08:00
										 
									 
								 
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								/sys/class/thermal:
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								|thermal_zone1:
							 | 
						
					
						
							
								
									
										
										
										
											2009-10-26 08:38:59 +01:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								    |---type:			acpitz
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    |---temp:			37000
							 | 
						
					
						
							
								
									
										
										
										
											2012-07-25 10:11:00 +08:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								    |---mode:			enabled
							 | 
						
					
						
							
								
									
										
										
										
											2012-09-18 11:05:06 +05:30
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								    |---policy:			step_wise
							 | 
						
					
						
							
								
									
										
										
										
											2009-10-26 08:38:59 +01:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								    |---trip_point_0_temp:	100000
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    |---trip_point_0_type:	critical
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    |---trip_point_1_temp:	80000
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    |---trip_point_1_type:	passive
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    |---trip_point_2_temp:	70000
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    |---trip_point_2_type:	active0
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    |---trip_point_3_temp:	60000
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    |---trip_point_3_type:	active1
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    |---cdev0:			--->/sys/class/thermal/cooling_device0
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    |---cdev0_trip_point:	1	/* cdev0 can be used for passive */
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    |---cdev1:			--->/sys/class/thermal/cooling_device3
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    |---cdev1_trip_point:	2	/* cdev1 can be used for active[0]*/
							 | 
						
					
						
							
								
									
										
										
										
											2008-01-17 15:51:08 +08:00
										 
									 
								 
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								|cooling_device0:
							 | 
						
					
						
							
								
									
										
										
										
											2009-10-26 08:38:59 +01:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								    |---type:			Processor
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    |---max_state:		8
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    |---cur_state:		0
							 | 
						
					
						
							
								
									
										
										
										
											2008-01-17 15:51:08 +08:00
										 
									 
								 
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								|cooling_device3:
							 | 
						
					
						
							
								
									
										
										
										
											2009-10-26 08:38:59 +01:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								    |---type:			Fan
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    |---max_state:		2
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    |---cur_state:		0
							 | 
						
					
						
							
								
									
										
										
										
											2008-04-22 08:50:09 +08:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								/sys/class/hwmon:
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								|hwmon0:
							 | 
						
					
						
							
								
									
										
										
										
											2009-10-26 08:38:59 +01:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								    |---name:			acpitz
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    |---temp1_input:		37000
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								    |---temp1_crit:		100000
							 | 
						
					
						
							
								
									
										
										
										
											2010-10-27 03:33:29 +05:30
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								4. Event Notification
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								The framework includes a simple notification mechanism, in the form of a
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								netlink event. Netlink socket initialization is done during the _init_
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								of the framework. Drivers which intend to use the notification mechanism
							 | 
						
					
						
							
								
									
										
										
										
											2011-11-04 10:31:04 +01:00
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								just need to call thermal_generate_netlink_event() with two arguments viz
							 | 
						
					
						
							
								
									
										
										
										
											2010-10-27 03:33:29 +05:30
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								(originator, event). Typically the originator will be an integer assigned
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								to a thermal_zone_device when it registers itself with the framework. The
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								event will be one of:{THERMAL_AUX0, THERMAL_AUX1, THERMAL_CRITICAL,
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								THERMAL_DEV_FAULT}. Notification can be sent when the current temperature
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								crosses any of the configured thresholds.
							 | 
						
					
						
							
								
									
										
										
										
											2012-09-18 11:05:06 +05:30
										 
									 
								 
							 | 
							
								
									
										
									
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								5. Export Symbol APIs:
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								5.1: get_tz_trend:
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								This function returns the trend of a thermal zone, i.e the rate of change
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								of temperature of the thermal zone. Ideally, the thermal sensor drivers
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								are supposed to implement the callback. If they don't, the thermal
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								framework calculated the trend by comparing the previous and the current
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								temperature values.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								5.2:get_thermal_instance:
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								This function returns the thermal_instance corresponding to a given
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								{thermal_zone, cooling_device, trip_point} combination. Returns NULL
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								if such an instance does not exist.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								5.3:notify_thermal_framework:
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								This function handles the trip events from sensor drivers. It starts
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								throttling the cooling devices according to the policy configured.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								For CRITICAL and HOT trip points, this notifies the respective drivers,
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								and does actual throttling for other trip points i.e ACTIVE and PASSIVE.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								The throttling policy is based on the configured platform data; if no
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								platform data is provided, this uses the step_wise throttling policy.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								5.4:thermal_cdev_update:
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								This function serves as an arbitrator to set the state of a cooling
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								device. It sets the cooling device to the deepest cooling state if
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								possible.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								5.5:thermal_register_governor:
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								This function lets the various thermal governors to register themselves
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								with the Thermal framework. At run time, depending on a zone's platform
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								data, a particular governor is used for throttling.
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								5.6:thermal_unregister_governor:
							 | 
						
					
						
							| 
								
							 | 
							
								
							 | 
							
								
							 | 
							
							
								This function unregisters a governor from the thermal framework.
							 |