164 lines
		
	
	
	
		
			4.2 KiB
			
		
	
	
	
		
			C
		
	
	
	
	
	
		
		
			
		
	
	
			164 lines
		
	
	
	
		
			4.2 KiB
			
		
	
	
	
		
			C
		
	
	
	
	
	
|   | /*
 | ||
|  |  * Power supply driver for testing. | ||
|  |  * | ||
|  |  * Copyright 2010  Anton Vorontsov <cbouatmailru@gmail.com> | ||
|  |  * | ||
|  |  * This program is free software; you can redistribute it and/or modify | ||
|  |  * it under the terms of the GNU General Public License version 2 as | ||
|  |  * published by the Free Software Foundation. | ||
|  |  */ | ||
|  | 
 | ||
|  | #include <linux/kernel.h>
 | ||
|  | #include <linux/module.h>
 | ||
|  | #include <linux/power_supply.h>
 | ||
|  | #include <linux/errno.h>
 | ||
|  | #include <linux/delay.h>
 | ||
|  | #include <linux/vermagic.h>
 | ||
|  | 
 | ||
|  | static int test_power_ac_online = 1; | ||
|  | static int test_power_battery_status = POWER_SUPPLY_STATUS_CHARGING; | ||
|  | 
 | ||
|  | static int test_power_get_ac_property(struct power_supply *psy, | ||
|  | 				      enum power_supply_property psp, | ||
|  | 				      union power_supply_propval *val) | ||
|  | { | ||
|  | 	switch (psp) { | ||
|  | 	case POWER_SUPPLY_PROP_ONLINE: | ||
|  | 		val->intval = test_power_ac_online; | ||
|  | 		break; | ||
|  | 	default: | ||
|  | 		return -EINVAL; | ||
|  | 	} | ||
|  | 	return 0; | ||
|  | } | ||
|  | 
 | ||
|  | static int test_power_get_battery_property(struct power_supply *psy, | ||
|  | 					   enum power_supply_property psp, | ||
|  | 					   union power_supply_propval *val) | ||
|  | { | ||
|  | 	switch (psp) { | ||
|  | 	case POWER_SUPPLY_PROP_MODEL_NAME: | ||
|  | 		val->strval = "Test battery"; | ||
|  | 		break; | ||
|  | 	case POWER_SUPPLY_PROP_MANUFACTURER: | ||
|  | 		val->strval = "Linux"; | ||
|  | 		break; | ||
|  | 	case POWER_SUPPLY_PROP_SERIAL_NUMBER: | ||
|  | 		val->strval = UTS_RELEASE; | ||
|  | 		break; | ||
|  | 	case POWER_SUPPLY_PROP_STATUS: | ||
|  | 		val->intval = test_power_battery_status; | ||
|  | 		break; | ||
|  | 	case POWER_SUPPLY_PROP_CHARGE_TYPE: | ||
|  | 		val->intval = POWER_SUPPLY_CHARGE_TYPE_FAST; | ||
|  | 		break; | ||
|  | 	case POWER_SUPPLY_PROP_HEALTH: | ||
|  | 		val->intval = POWER_SUPPLY_HEALTH_GOOD; | ||
|  | 		break; | ||
|  | 	case POWER_SUPPLY_PROP_TECHNOLOGY: | ||
|  | 		val->intval = POWER_SUPPLY_TECHNOLOGY_LION; | ||
|  | 		break; | ||
|  | 	case POWER_SUPPLY_PROP_CAPACITY_LEVEL: | ||
|  | 		val->intval = POWER_SUPPLY_CAPACITY_LEVEL_NORMAL; | ||
|  | 		break; | ||
|  | 	case POWER_SUPPLY_PROP_CAPACITY: | ||
|  | 		val->intval = 50; | ||
|  | 		break; | ||
|  | 	case POWER_SUPPLY_PROP_TIME_TO_EMPTY_AVG: | ||
|  | 	case POWER_SUPPLY_PROP_TIME_TO_FULL_NOW: | ||
|  | 		val->intval = 3600; | ||
|  | 		break; | ||
|  | 	default: | ||
|  | 		pr_info("%s: some properties deliberately report errors.\n", | ||
|  | 			__func__); | ||
|  | 		return -EINVAL; | ||
|  | 	} | ||
|  | 	return 0; | ||
|  | } | ||
|  | 
 | ||
|  | static enum power_supply_property test_power_ac_props[] = { | ||
|  | 	POWER_SUPPLY_PROP_ONLINE, | ||
|  | }; | ||
|  | 
 | ||
|  | static enum power_supply_property test_power_battery_props[] = { | ||
|  | 	POWER_SUPPLY_PROP_STATUS, | ||
|  | 	POWER_SUPPLY_PROP_CHARGE_TYPE, | ||
|  | 	POWER_SUPPLY_PROP_HEALTH, | ||
|  | 	POWER_SUPPLY_PROP_TECHNOLOGY, | ||
|  | 	POWER_SUPPLY_PROP_CHARGE_FULL, | ||
|  | 	POWER_SUPPLY_PROP_CHARGE_EMPTY, | ||
|  | 	POWER_SUPPLY_PROP_CAPACITY, | ||
|  | 	POWER_SUPPLY_PROP_CAPACITY_LEVEL, | ||
|  | 	POWER_SUPPLY_PROP_TIME_TO_EMPTY_AVG, | ||
|  | 	POWER_SUPPLY_PROP_TIME_TO_FULL_NOW, | ||
|  | 	POWER_SUPPLY_PROP_MODEL_NAME, | ||
|  | 	POWER_SUPPLY_PROP_MANUFACTURER, | ||
|  | 	POWER_SUPPLY_PROP_SERIAL_NUMBER, | ||
|  | }; | ||
|  | 
 | ||
|  | static char *test_power_ac_supplied_to[] = { | ||
|  | 	"test_battery", | ||
|  | }; | ||
|  | 
 | ||
|  | static struct power_supply test_power_supplies[] = { | ||
|  | 	{ | ||
|  | 		.name = "test_ac", | ||
|  | 		.type = POWER_SUPPLY_TYPE_MAINS, | ||
|  | 		.supplied_to = test_power_ac_supplied_to, | ||
|  | 		.num_supplicants = ARRAY_SIZE(test_power_ac_supplied_to), | ||
|  | 		.properties = test_power_ac_props, | ||
|  | 		.num_properties = ARRAY_SIZE(test_power_ac_props), | ||
|  | 		.get_property = test_power_get_ac_property, | ||
|  | 	}, { | ||
|  | 		.name = "test_battery", | ||
|  | 		.type = POWER_SUPPLY_TYPE_BATTERY, | ||
|  | 		.properties = test_power_battery_props, | ||
|  | 		.num_properties = ARRAY_SIZE(test_power_battery_props), | ||
|  | 		.get_property = test_power_get_battery_property, | ||
|  | 	}, | ||
|  | }; | ||
|  | 
 | ||
|  | static int __init test_power_init(void) | ||
|  | { | ||
|  | 	int i; | ||
|  | 	int ret; | ||
|  | 
 | ||
|  | 	for (i = 0; i < ARRAY_SIZE(test_power_supplies); i++) { | ||
|  | 		ret = power_supply_register(NULL, &test_power_supplies[i]); | ||
|  | 		if (ret) { | ||
|  | 			pr_err("%s: failed to register %s\n", __func__, | ||
|  | 				test_power_supplies[i].name); | ||
|  | 			goto failed; | ||
|  | 		} | ||
|  | 	} | ||
|  | 
 | ||
|  | 	return 0; | ||
|  | failed: | ||
|  | 	while (--i >= 0) | ||
|  | 		power_supply_unregister(&test_power_supplies[i]); | ||
|  | 	return ret; | ||
|  | } | ||
|  | module_init(test_power_init); | ||
|  | 
 | ||
|  | static void __exit test_power_exit(void) | ||
|  | { | ||
|  | 	int i; | ||
|  | 
 | ||
|  | 	/* Let's see how we handle changes... */ | ||
|  | 	test_power_ac_online = 0; | ||
|  | 	test_power_battery_status = POWER_SUPPLY_STATUS_DISCHARGING; | ||
|  | 	for (i = 0; i < ARRAY_SIZE(test_power_supplies); i++) | ||
|  | 		power_supply_changed(&test_power_supplies[i]); | ||
|  | 	pr_info("%s: 'changed' event sent, sleeping for 10 seconds...\n", | ||
|  | 		__func__); | ||
|  | 	ssleep(10); | ||
|  | 
 | ||
|  | 	for (i = 0; i < ARRAY_SIZE(test_power_supplies); i++) | ||
|  | 		power_supply_unregister(&test_power_supplies[i]); | ||
|  | } | ||
|  | module_exit(test_power_exit); | ||
|  | 
 | ||
|  | MODULE_DESCRIPTION("Power supply driver for testing"); | ||
|  | MODULE_AUTHOR("Anton Vorontsov <cbouatmailru@gmail.com>"); | ||
|  | MODULE_LICENSE("GPL"); |