|   | Kernel driver max6639 | ||
|  | ===================== | ||
|  | 
 | ||
|  | Supported chips: | ||
|  |   * Maxim MAX6639 | ||
|  |     Prefix: 'max6639' | ||
|  |     Addresses scanned: I2C 0x2c, 0x2e, 0x2f | ||
|  |     Datasheet: http://pdfserv.maxim-ic.com/en/ds/MAX6639.pdf | ||
|  | 
 | ||
|  | Authors: | ||
|  |     He Changqing <hechangqing@semptian.com> | ||
|  |     Roland Stigge <stigge@antcom.de> | ||
|  | 
 | ||
|  | Description | ||
|  | ----------- | ||
|  | 
 | ||
|  | This driver implements support for the Maxim MAX6639. This chip is a 2-channel | ||
|  | temperature monitor with dual PWM fan speed controller. It can monitor its own | ||
|  | temperature and one external diode-connected transistor or two external | ||
|  | diode-connected transistors. | ||
|  | 
 | ||
|  | The following device attributes are implemented via sysfs: | ||
|  | 
 | ||
|  | Attribute              R/W  Contents | ||
|  | ---------------------------------------------------------------------------- | ||
|  | temp1_input            R    Temperature channel 1 input (0..150 C) | ||
|  | temp2_input            R    Temperature channel 2 input (0..150 C) | ||
|  | temp1_fault            R    Temperature channel 1 diode fault | ||
|  | temp2_fault            R    Temperature channel 2 diode fault | ||
|  | temp1_max              RW   Set THERM temperature for input 1 | ||
|  |                             (in C, see datasheet) | ||
|  | temp2_max              RW   Set THERM temperature for input 2 | ||
|  | temp1_crit             RW   Set ALERT temperature for input 1 | ||
|  | temp2_crit             RW   Set ALERT temperature for input 2 | ||
|  | temp1_emergency        RW   Set OT temperature for input 1 | ||
|  |                             (in C, see datasheet) | ||
|  | temp2_emergency        RW   Set OT temperature for input 2 | ||
|  | pwm1                   RW   Fan 1 target duty cycle (0..255) | ||
|  | pwm2                   RW   Fan 2 target duty cycle (0..255) | ||
|  | fan1_input             R    TACH1 fan tachometer input (in RPM) | ||
|  | fan2_input             R    TACH2 fan tachometer input (in RPM) | ||
|  | fan1_fault             R    Fan 1 fault | ||
|  | fan2_fault             R    Fan 2 fault | ||
|  | temp1_max_alarm        R    Alarm on THERM temperature on channel 1 | ||
|  | temp2_max_alarm        R    Alarm on THERM temperature on channel 2 | ||
|  | temp1_crit_alarm       R    Alarm on ALERT temperature on channel 1 | ||
|  | temp2_crit_alarm       R    Alarm on ALERT temperature on channel 2 | ||
|  | temp1_emergency_alarm  R    Alarm on OT temperature on channel 1 | ||
|  | temp2_emergency_alarm  R    Alarm on OT temperature on channel 2 |